Nanchang Guangming Laboratory Assay Equipment Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Luo Cynthia
  • Company Name : Nanchang Guangming Laboratory Assay Equipment Co., Ltd.
  • Tel : 86-791-88113882
  • Fax : 86-791-88631473
  • Address : Jiangxi,Nanchang,No.666, Science And Technology Road, Private Science and Technology Park, Nanchang City, Jiangxi Province
  • Country/Region : China
  • Zip : 330096

Automatic Calorimeter (Temperature-controlled type)

Automatic Calorimeter (Temperature-controlled type)
Product Detailed
Automatic Calorimeter (temperatufd-controlled type) test material of low calorific valuable. automatically use the heat cap.

Automatic Calorimeter (Temperature-controlled type)

Features:

1. Professionally designed 4-layer PCB and surface mount technology improve the stability and anti-interference of the equipment.

2. Unique ultra-high-bit analog to digital conversion technology: adopting 24-bit analog-to-digital converter with high precision and stability imported from American, which makes the higher precision.

3. Sensor probe adopts the thin-film platinum resistance with high-precision and stability imported from German, full-silver tube sheathed.

4. Widows interface: Using the most advanced object-oriented software design techniques, which can connect several intelligent analyzers connected to form an analysis system.

5. Advanced Serial Bus technology: The instrument uses advanced RS485 or 485 serial bus, connect the computer by a two-core data communications cable, which makes it possible to control several analyzers(maximum:32 sets)

6. Original constant-volume water compensation technology, which improves the measurement accuracy greatly.

7. Accurate Refrigeration Technology: adopting domestic advanced "circulating water cooling technology", which makes water temperature return to starting value quickly to ensure the accuracy of the test.

8. The volume of calorimeter tank is up to 60kg, and the water circulating adopts two high-powered magnetic pumps imported from German, without solenoid valve, this instrument is one of the most popular instruments .

9. Particularly suitable for testing material of low calorific value.

10. The instrument has function of automatic identification to A, B oxygen bomb, and it will automatically use the heat capacity separately to avoid the man-made input errors.

 

Technical parameter: 

GMC6000 Automatic calorimeter

Model no.

GMC6000/L

Vertical type

GMC6000/T

Temperature-controlled type

GMC6000/W

Horizontal type

GMC6000/P

Normal type

Testing time

Normal way: about 15min

Quick way: about8min

Normal way: about 18min

Quick way: about8min

Normal way: about 15min

Quick way: about8min

Normal way: about 15min

Temperature testing range

5~40

5~40

5~40

5~40

Resolutions

0.0001

0.0001

0.0001

0.0001

Precision

RSD≤0.1%

RSD≤0.1%

RSD≤0.1%

RSD≤0.2%

Power

≤500W

≤1.5kw

(Cooling power≤100w

heating power≤1 kw)

≤500W

≤200W

Working power supply

220±22VAC ; (50±1)HZ

220±22VAC; (50±1)HZ

220±22VAC; (50±1)HZ

220±22VAC; (50±1)HZ

Automatic Calorimeter (Temperature-controlled type)



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.